Customization: | Available |
---|---|
Type: | Syringe |
Syringe: | Disposable Sterile Syringe |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Unique rotary number setter, easy and quick parameter setting
Swift priming and flushing function available
Memory and recall function for previous setting
Ultrasonic bubble detection technology
Instant detection of dynamic pressure, facilitating clinical monitoring&prediction, and lowering occlusion risks
Embedded handle for better space efficiency
Exclusive/universal feeding sets, higher feeding accuracy and lower occlusion risks
Infusion rate (ml/h)
|
1~400 ml/hr in 1 ml increments
|
Mean flow velocity accuracy
|
±10% of selected flow rate
|
Dosage limit(ml)
|
0-9999 in 1 ml increment
|
Meanvolume accuracy
|
±10%
|
Loading speed andmeanaccuracy (ml/h) |
1000±10%
|
Cleaning speed andmeanspeedaccuracy(ml/h) |
1000±10%
|
Max volume flushandmeanspeed accuracy(ml) |
40±10%
|
Mx feeding pump pressure
|
≥0.1 MPa
|
Occlusion alarm level (pressure)
|
50KPa±10KPa
|
The longest occlusion triggering time of this device at minimum flow rate |
43min
|
The shortest occlusion triggering time of this device at intermediate flow rate |
85s
|
Medium speed running the pills from blocking the alarm threshold |
0.79ml
|
Recoverable Alarm
|
1min50s-2min
|
Pause overtime alarm time
|
1min50s-2min
|
Heating temperature
|
Infusion flow rate ≥20ml / h, 375px distance away from the heater outlet at 25-38 ºC |
Use ofinfusionset
|
See recommended infusion sets list
|
Air-in-line sensitivity
|
Detestability of single size of air bubble ≥50uL
|
Alarm
|
Occlusion alarm, Over heatedalarm, battery depleted alarm |
Alarms
|
Air in line,Prime, Flush, low power, failurecodes (ERxx), pause overtime, powerstate, infusion mode, work state, heaterstate. |
Noise
|
Measured at the highest flow rate on wooden table, the volume is lower than 50 dB at a distance of 1 meter |
Power
|
Ac: 100V-240V 50 Hz /60Hz
|
Built inbattery
|
A fully charged internal DC11.1V battery can continuously run the pump for approximately 5 hours on intermediate rate |
Power consumption
|
≤40VA
|
Power output
|
≤20VA
|
The rated output voltage
|
15V
|
Weight
|
2.0kg
|
Heater
|
W-E01 ,cable length is 1.5m,Shield
|
Essential performance
|
This product is suitable for patients with enteral nutrition infusion, the host cancontrol the infusion rate. With alarmfunction, with bubble detection piping and piping blockage detection. |
Classification
|
type BF,class ΙΙ continuous volumetric feeding pump with internal battery; IPX1 (sealed drip-proof device) |
Dimensions
|
155mm(L)×170mm(W)×180mm(H)
|
Accessories
|
1 user manual, 1 power cable, 1 heater (EA312/313 models only) |
Forever Medical supplies different kinds of products. High quality and favorable price. We're pleased to get your Inquiry and we will come back to as soon as possible. We stick to the principle of "quality first, service first, continuous improvement and innovation to meet the customers" for the management and "zero defect, zero complaints" as the quality objective. To perfect our service, we provide the products with good quality at the reasonable price.