Hospital Surgical Anaesthesia Monitors Equipment
Product Description
YJ-PA01 with 1 vaporizer Multifunctional Anesthesia machine
CE, ISO 13485 and Rohs certificates
Pneumatically driven and electrically controlled system
Built-in ventilator, 5.4" LCD display screen
Closed; Semi-Closed; Semi-Open working mode
Applied for Adult and Pediatric
Main technical specifications:
Gas requirement:
Medical oxygen and nitrous oxide with a pressure ranging from O2 & NO2: 0.32~0.6 MPa.
4-tubes Flowmeters, O 2 & N 2 O; 0.1L/Min ~ 10L / Min;
Oxygen Flush: 25~75 L / Min
Respiration Mode: A/C,IPPV,SIPPV,IMV,SIMV,MANUAL
Tidal Volume: 0~1500ml
I/E Ratio: 4:1 ~ 1:10
One vaporizer: Enflurane/ Isoflurane/Sevoflurane/Halothane
Vaporizer Setting Range: 0.5%~5%
Respiration Frequency : 1~99 bpm;
Ptr: -1.0kPa ~ 1.0 kPa
CO 2 absorber capacity : 1 kg
Optional: Patient monitor
Alarm parameters:
upper/lower limit of airway pressure,tital volume exceed limitation,no tidal volume output,apnea,AC power malfunction,Battery low power.
Product Features:
Operating Modes: Pneumatically driven & electronically controlled, closed, semi-closed and semi-open
Anesthesia Ventilator: Built-in ventilator, 5.4" LCD display screen
Standard integrated metallic modular respiratory circuit; completely solves the problem of gas sealing under high temperature disinfection, easy to clean and disinfect
Equipped with electronic pressure differential flow sensor, imported respiratory control valve
Vaporizer: Imported tank components assembled locally; Enflurane, Isoflurane and Sevoflurane (Halothane optional). Also possesses self-compensating functionality
Multi-parameter Patient Monitor: Optional
High precision four tube flowmeter, fitted with interlocking oxygen-nitrous oxide supply, guarantees oxygen output is never lower than 21%
Nonhazardous environmentally friendly frame, with automated self-checking function during startup and an automatic
self-calibrating sensor
Power Failure Support Functions: Automatically converts to backup power mode during AC power outages
Alarms: Audible and/or visual alarms for tidal volume, airway pressure, asphyxia, power failure, oxygen failure and other alarms, also features a alarm query function
Equipped with advanced international rotating Na-lime tank, uses imported PPSU material and temperature resistant to 134°C
Main Specifications
Model No. |
YJ-PA01 Anesthesia Machine |
Display |
5.4" LCD display screen |
Flowmeter Range |
O2: 0.1-10L/min |
N2O: 0.1-10L/min |
Ventilation Mode |
A/C,IPPV,SIPPV,MANUAL |
Back-up Power Supply |
At least 4 hours |
Tidal Volume |
Adjustable range: 50-1500ml |
Display range: 0-1500ml |
Respiratory Rate |
1-99bpm |
Inspiratory/Expiratory (I:E) Ratio |
4:1 ~ 1:10 |
Inspiratory Pressure Trigger Range |
-10-10cmH2O (electronically controlled) |
Vaporizer Concentration Ranges |
0-5% |