Features:
large screen high-resolution colorful display, low radiation, clear and bright image.
1 High-definition and colorful display
2 Multiple function and easy operation
3 Radiationless,no-invasive,long life-time
4 Mouse action, convenient operation
The function of the mode of mammography :
1 Detect galactocele accurately;
2 Detect intraductal papilloma;
3 Detect mammary duct ectasia and acute mastitis:
4 Detect proliferation of mammary gland and breast cancer.
Comfortable Compression of the mode of mammography
When some degree of pressure is required for radiography, it allows you to presser the appropriate pressure(up to a maximum of 20kg)and is equipped with MICOM Control's Soft-touch system which is designed to minimize the discomfort of the examine within the pressure range.
Tissue Compression: Manual and Motorized (Max 20kg)
Compression Force and Thickness Data Display
Micro Control's Compression
Automatic Release
No. | Item | Specification |
1 | X-ray Generator | |
1.1 | Generator Type | High Frequency Inverter 80kHz |
1.2 | Input Power | Single Phase 220VAC, 50/60Hz |
1.3 |
Radiographic Ratings |
Large Focal Point 20-35kV/10-510mAs |
Small Focal Point 20-35kV/10-100mAs | ||
1.4 | Power Rating | 6.2kW |
2 | X-ray Tube | |
2.1 | Model | China LR01 |
2.2 | Focal Spot Size | Dual Focus 0.2 / 0.4mm |
2.3 | Target Material | Molybdenum (Mo) |
2.4 | Port Material | Beryllium (Be) |
2.5 | High-speed Anode Drive | 2800rpm |
2.6 | Target Angle | 12° |
2.7 | Anode Heat Storage | 80kJ(110kHU) |
2.8 | Anode Cooling | Air Cooling |
2.9 | Filtration | Mo(0.03mm) |
3 | Radiographic Stand | |
3.1 | U-arm Vertical Movement | 590mm |
3.2 | Rotations Deg | +90° ~-90° |
3.3 | SID | 650mm |
3.4 | Compressor | The compressor is automatically released after the exposure is completed |
3.5 | Compressor Max. Pressure | 200N |
3.6 | Compressor Max. Travel | 156mm |
No. | Item | Specification |
4 | Detector | |
4.1 | Detector Material | Amorphous Silicon |
4.2 | Effective Coverage Of Detector |
24cm ×30cm |
4.3 | Pixel Matrix | 2816 ×3528 |
4.4 | Limit Of Spatial Resolution | 6.0Lp/mm |
4.5 | DQE Value | @4 Lp/mm:≥35% |
4.6 | Dynamic Range | 14bit Digital Output |
4.7 | Pixel Size | 85μm |
4.8 | Output | Ethernet |
4.9 | Working Condition | 10ºC-40ºC |
4.10 | Storage Environment | -10ºC-50ºC |
5 | Image Acquisition Workstation Hardware |
|
5.1 | CPU | Intel Core Duo 3.0GHz |
5.2 | Hardware | ≥1T high Speed Hardware |
5.3 | Memory | ≥8G |
5.4 | Display Card | ≥2G |
5.5 | High Brightness High-contrast LCD |
1920*1080Pixel Resolution |
5.6 |
Network interface Worklist |
DICOM3.0 Transmission |
100/1000 Gigabit Ethernet | ||
5.7 | Software | Imaging Software Package DMOC V1.0 |